Vertiv NPSII 60 AMP 3 Pole NPS-II FL3 DatasheetΒ 

The Vertiv Network Power Switch (NPS) is a remote power management device designed for networking equipment, data centers, and IT infrastructure. It enables users to control, monitor, and reboot connected devices via a network interface, improving uptime and operational efficiency.

Intelligent static transfer switches

Network Power Switch - I, Network Power Switch – II

Ensures maximum reliability to critical loads by eliminating system failures that are caused by power distribution problems.

The NPS-I & NPS-II switches allows instantaneous transfer of load between two power sources. It can be used to ensure complete redundancy of power supply upto the last piece of wire. It is useful in many applications, where redundant power supply is available, either from two UPS systems or one UPS and bypass source.

These switches are comprising of semiconductor switches, they ensure continuity of power to the load in the event of failure of one of the power sources. They have different user selectable parameters and in-built microprocessor.

Vertiv NPS-II FL3 – 60 A (3-Pole) Technical Specifications

Parameter

Specification

Ampere Rating

60 A

Input / Output

3 Phase

No. of Switching Poles

3 Pole (Ph)

Nominal Output Current

60 A

Nominal Voltage

400 / 415 V (3 Ph + N)

Voltage Tolerance

Low band: βˆ’30% to +15% (Default), Medium band: βˆ’25% to +15%, Narrow band: βˆ’15% to +15%

Nominal Frequency

Nominal: 48–52 Hz, Wide: 40–70 Hz (Default)

Efficiency

> 98%

Overload Capacity

110% for 1 hour, 150% for 1 min, 1000% for 100 ms

Duty

Continuous

Protections

Input Under Voltage, Input Over Voltage, Output Overload, Output Short Circuit

Transfer / Retransfer Time

Low Sensitivity: < 8 ms, Medium Sensitivity: < 5 ms (Default), High Sensitivity: < 3 ms

Manual Bypass Facility

Provided

Acoustic Noise Level

< 60 dBA

Operating Temperature

0 to 40Β°C

Relative Humidity

Up to 95% (Non-condensing)

Altitude

< 1000 m above sea level (without derating)

Testing Standard

IEC 62310-3

Enclosure Protection

IP 20

Cooling

Forced Cooling

Dimensions (W Γ— D Γ— H)

800 Γ— 600 Γ— 1750 mm

Weight

225 kg (approx.)

Color

RAL 7021

LCD Display Parameters

Source 1 R/Y/B Phase Voltage, Source 2 R/Y/B Phase Voltage, Source 1 Priority, Source 2 Priority, Output Load R/Y/B, Sensitivity Low/Medium/High, Date & Time

LED Indications

Source 1 Healthy, Source 2 Healthy, Source 1 Feeding, Source 2 Feeding

Fault Indications

SPP, Overload

Communication Interface

RS-485 Modbus (optional)