Veracity VLS-LSM-CXT LONGSPAN Max (Camera) XT EXTERNAL LONG RANGE ETHERNET
Veracity VLS-LSM-CXT LONGSPAN Max (Camera) XT EXTERNAL LONG RANGE ETHERNET
Any LONGSPAN Base unit (standard, Max or Base 8) may be used in conjunction with LONGSPAN Max XT camera. For maximum POE delivery, a LONGSPAN Max Base is recommended with a 100W PSU as shown. As LONGSPAN Max XT is designed for external use, there is no direct DC power connection and it must be powered by POE through the network cable.
- External version of LONGSPAN Max Camera
- Long range point-to-point Ethernet over Cat5e or Cat6 cable
- Unrestricted 100Base-TX at up to 820 metres
- Can deliver 60W at 200 metres, 40W at 350 metres
- Sleek housing & cable glands rated to IP66/67/69- & Nema 4X/6
- Smart power and diagnostic display for reliable installation
SPECIFICATION
POWER
Device Power Consumption : Up to 2W (under maximum POE load)
POE In (from Base) : Maximum POE delivered over LONGSPAN link depends on Base output, cable distance and cable quality
POE Out (to Camera) : IEEE 802.3bt output
LONGSPAN INTERFACE
Connector : RJ45 in a weatherproof gland
Cable : Cat6, Cat5e (3 sizes of grommet included for 4.7mm - 9mm cable diameter) Patch wiring recommended, other wiring auto-corrected
Rate : 200Mbps (100Mbps full-duplex) up to 820 metres [2,690ft] (Cat6)
ETHERNET INTERFACE
Connector : RJ45 in a weatherproof gland
Cable : Cat6, Cat5e (3 sizes of grommet included for 4.7mm - 9mm cable diameter) Patch or crossover, auto-detected
Rate : 100Base-TX full-duplex with auto-negotiation
LED INDICATORS
Ethernet RJ45 : Yellow: Link/activity, Green: power good
LONGSPAN Link RJ45 : Yellow: Link/activity, Green: 10/100Mbps
POE Power Level : P1 to P8 display code (indicating 5W to 70W POE available)
Error Status : E1 to E8 error code display (indicating as below)
E1 POE power draw exceeded ,E2 POE too low, disabled ,E3 POE to Camera overload, E4 POE to Camera short-circuit, E5 POE Camera signature error, E6 POE OK, no LONGSPAN link, E7 Cable wiring error E8 Poor kit (connection refused)
PHYSICAL/ENVIRONMENTAL
Dimensions : W 113mm, H 144mm (inc glands), D 69mm (incl. bracket) [ W 4.45in, H 5.67in (inc glands), D 2.72in (incl. bracket) ]
Weight : 350g [ 12.35oz ] incl. mounting bracket
Operating Temperature : -40°C to 70°C [ -40°F to 158°F ]
Relative Humidity : 85% non-condensing
Compliance : FCC, CE, RoHS, UKCA, IP66, 67, 69K, NEMA 4X, 6, BS EN 50121-4 (rail + metro)